-20%
LC1D65P7 – TeSys Deca contactor,3P(3NO),AC-3/AC-3e/<=440V 65A,230V AC 50/60Hz coil
Original price was: NGN248,382.23.NGN198,705.78Current price is: NGN198,705.78.
TeSys Deca contactor, 3 poles (3NO),for motor control applications 65A/690V,AC-3 37kW@690V. and for non-inductive load control applications up to 80A@60℃ in category AC-1. It provides a 230V 50/60Hz AC coil,1NO/1NC built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EN).
20 people are viewing this right now
Description
Reviews (0)
Description
| Range | TeSys |
|---|---|
| Range of product | TeSys Deca |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Motor control Resistive load |
| Utilisation category | AC-2 AC-4 AC-1 AC-3e AC-1 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 25…400 Hz |
| [Ie] rated operational current | 65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit 65 A (at <60 °C) at 230 V AC AC-3 for power circuit 80 A (at <60 °C) at 230 V AC AC-1 for power circuit |
| [Uc] control circuit voltage | 230 V AC 50/60 Hz |
| Motor power kW | 11 kW at 400 V AC 50 Hz (AC-4) 30 kW at 380…400 V AC 50 Hz (AC-3) 37 kW at 500 V AC 50 Hz (AC-3) 37 kW at 660…690 V AC 50 Hz (AC-3) 18.5 kW at 220…230 V AC 50 Hz (AC-3) 30 kW at 415 V AC 50 Hz (AC-3) 37 kW at 1000 V AC 50 Hz (AC-3) 30 kW at 440 V AC 50 Hz (AC-3e) 37 kW at 500 V AC 50 Hz (AC-3e) 37 kW at 660…690 V AC 50 Hz (AC-3e) 18.5 kW at 220…230 V AC 50 Hz (AC-3e) 30 kW at 415 V AC 50 Hz (AC-3e) 37 kW at 1000 V AC 50 Hz (AC-3e) 37 kW at 500 V AC 50 Hz 30 kW at 380…400 V AC 50 Hz |
|---|---|
| Motor power hp | 10 hp at 230/240 V AC 60 Hz for 1 phase motors 20 hp at 200/208 V AC 60 Hz for 3 phases motors 20 hp at 230/240 V AC 60 Hz for 3 phases motors 40 hp at 460/480 V AC 60 Hz for 3 phases motors 50 hp at 575/600 V AC 60 Hz for 3 phases motors 5 hp at 115 V AC 60 Hz for 1 phase motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 80 A (at 60 °C) for power circuit 10 A (at 60 °C) for control circuit |
| Irms rated making capacity | 140 A at 440 V AC for control circuit conforming to IEC 60947-5-1 140 A AC for control circuit conforming to IEC 60947-5-1 1000 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 1000 kA at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 520 A 40 °C – 10 s for power circuit 900 A 40 °C – 1 s for power circuit |
| Associated fuse rating | 125 A gG at <= 690 V coordination type 2 for power circuit 160 A gG at <= 690 V coordination type 1 for power circuit conforming to IEC 60947-5-1 125 A gG at <= 690 V coordination type 1 for power circuit 10 A gG for control circuit conforming to IEC 60947-5-1 |
| Average impedance | 1.5 Ohm – Ith 80 A 50 Hz for power circuit |
| Power dissipation per pole | 6.4 W AC-1 4.2 W AC-3e 6.3 W AC-3 9.6 W AC-1 |
| [Ui] rated insulation voltage | Control circuit: 600 V UL certified Power circuit: 600 V CSA certified Power circuit: 600 V UL certified conforming to IEC 60947-1 Control circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V CSA certified conforming to IEC 60947-1 Control circuit: 600 V CSA certified |
| Overvoltage category | III |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 6000000 cycles |
| Control circuit type | AC at 50/60 Hz |
| Coil technology | Without built-in |
| Control circuit voltage limits | 0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz 0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz 1…1.1 Uc (60…70 °C):operational AC 50/60 Hz 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz |
| Inrush power in VA | 160 VA cos phi 0.75 (at 20 °C) 140 VA cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 15 VA 50 Hz cos phi 0.3 (at 20 °C) 13 VA 60 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 4…5 W at 50/60 Hz for control circuit |
| Operating time | 12…26 ms closing 4…19 ms opening |
| Maximum operating rate | 3600 cyc/mn at 60 °C |
| Connections – terminals | Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: rigid without cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: rigid Power circuit: screw clamp terminals 2 2.5…16 mm² – cable stiffness: rigid without cable end Power circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: flexible without cable end Power circuit: screw clamp terminals 2 2.5…16 mm² – cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: rigid Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: rigid |
| Tightening torque | Control circuit: 1.7 N.m – on screw clamp terminal – with screwdriver Philips No 2 Power circuit: 5 N.m – on screw terminal – with screwdriver flat Ø 6 to Ø 8 mm Control circuit: 1.7 N.m – on screw clamp terminal – with screwdriver pozidriv No 2 Control circuit: 1.7 N.m – on screw clamp terminal – with screwdriver flat Ø 6 mm |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mirror contact 1 NC conforming to IEC 60947-4-1 type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 |
| Minimum switching voltage | 17 V for control circuit |
| Minimum switching current | 5 mA for control circuit |
| Insulation resistance | > 10 MOhm for control circuit |
| Non-overlap time | 1.5 ms on energisation between NC and NO contacts 1.5 ms on de-energisation between NC and NO contacts |
| Mounting support | Rail Rail |
| Standards | IEC 60947-5-1 EN 60947-5-1 IEC 60947-4-1 EN 60947-4-1 CSA C22.2 No 14 |
|---|---|
| Product certifications | DNV GL BV CSA GOST UL RINA CCC UKCA RINA |
| IP degree of protection | IP2X conforming to VDE 0106 IP2X conforming to IEC 60529 |
| Protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat |
| Operating altitude | 0…3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Shocks contactor closed (15 Gn for 11 ms) Vibrations contactor opened (2 Gn, 5…300 Hz) Vibrations contactor closed (4 Gn, 5…300 Hz) Shocks contactor opened (10 Gn for 11 ms) |
| Height | 122 mm |
| Width | 70 mm |
| Depth | 118 mm |
| Net weight | 2.185 kg |
| Quantity per set | Set of 10 |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 9.5 cm |
| Package 1 Width | 13.5 cm |
| Package 1 Length | 14.0 cm |
| Package 1 Weight | 1.448 kg |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 5 |
| Package 2 Height | 15.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 7.481 kg |
Rating & Review
There are no reviews yet.